Autoclave
Introduction to the Autoclave for Advanced Processing of Glass
Our autoclaves for advanced processing of glass are developed under a series of test and research, and on the basis of drawing on the advantages of similar products of other countries. The equipment is used in hot-processing of sandwiched glass with gumming material under designated temperature and pressure. Inseparable adhesion between glass and gumming material will then be achieved after cooling and the sandwiched glass is made. Therefore, being a kinds of main equipment for advanced processing of glass, such autoclave is widely used in the automobile, aeronautical and space-flight industries, as well as building ornamentation, where normal or super anti-penetrating sandwiched glass would be used.

For the time being, a series of product with diameters of 1.65m, 2.0m, 2.5m, 2.85m, and 3m are available. The length of the autoclave can be designed and tailor-made to suit the user's need. Autoclaves are manufactured on production line, automatically welded, 100% nondestructive X-ray examination is carried out on welds of pressured parts. Test devices are advance. The production quality is stable and reliable. The hot-processing process is automatically carried out in accordance with the designed processing curve, and alarming devices for over-temperature and over-pressure are provided. The automation of production process is high, and it is safe and nimble to operate.

 
 
Constitutes of Autoclave
The equipment is composed of two subsystems with independent functions.
 
1、Autoclave Body
It is a horizontal pressure vessel with a door electrically operated. There are electric heating element, cooling device and stirring device installed, and also circulating air duct and trolley rail. Safety device for door opening is also provided.
 
2、Control System
There are two kinds of system available: manually and computer-controlled, which can be selected by the user.
By computer-controlled system, opening and closing operation of doors as well as the whole production process can be automatically controlled. Measuring instruments are mounted on the autoclave so that the temperature and pressure will be adjusted in accordance with the requirement of the process.
 

NO.

Description

Unit

Technical Specification

Model Number

FO-1.65x4D

FO-2x4.5D

FO-2.5x5.5D

FO-2.85x5.5D

FO-3x5.5D

1

Inside diameter

m

1.65

2

2.5

2.85

3

2

Length available

m

4

4.5

5.5

5.5

5.5

3

Designed pressure

Map

1.4

1.5

1.6

1.6

1.6

4

Designed temperature

oC

150

150

160

160

160

5

Working pressure

Map

1.3

1.4

1.5

1.5

1.5

6

Working temperature

oC

150

150

160

160

160

7

Medium

/

air

air

air

air

air

8

Rail gauge

mm

900

800

850

850

850

9

Electric heating capacity

KW

54

72

147

210

254

10

Total motor power

KW

8

11

22

22

22

11

Total weigh

t

5.8

8.65

15.1

21

24

12

Overall dimension(LxWxH)

m

5.71x2.36x2.74

7.24x2.6x3.2

8.82x2.97x4

8.572x3.44x4.7

8.9x3.4x4.8

13

Mode of opening

/

manual
opening

automatic
opening

automatic
opening

automatic
opening

automatic
opening

14

Volume of the gas tank

m3

6

6

10

15

20

15

Distance  from  the horizontal enterline of  shell  body  to the  surface  of rail

mm

615

860

1070

1250

1400

 
Note: Ready to design and manufacture according to user's requirements